Liquid Moisture Transmitter
Moisture Technology Application in lquids & Oil Industry
Ref:liqMS1204IntE 2001v1
n MS1204 Mircrowave Atenuation mothed
n Auto Temperature Compensation
n Less Influeency of Salinity
n 0.01-100% real time measurement
n Rugged, No maintenance running
n MS1204 Keep best specificaton all over 0.01%-100% application for oil
n Specially used to oil field, petroleum.refinery plant, and other chemical process
n IEEE1451.2 STIM Transducer, 0/4-20mA outputs and RS232/RS485 seriel communication port.
n IEEE1451.1 NCAP analyzer/controller, new design for new century network instruments.
MS1204 series Moisture Sensor:MS1204 is one experienced design of high frequicy complex technology, so it just overcomes the shortcomings of being too dumb as that of microwave and too sensitive as that of capacity technology. Combined with modern instrumental technology,such as temperature compensation etc. MS1204 keep 0.01 stable resolution to moisture in oil, but less sensitive to dissolved salts, for it is very important in application in oil field, and best accuracy among 70-100% moisture content is expected.
Principle for MS1204 Moisture Detect
Because of the high polarity of water molecules, water behaves more sensitive than any other materials in high frequency electronic magnetic field. MS1204 series is simply designed based on this verified physical property. In the chamber of the sensor applied stable HF power, the water and other materials all exhaust the energy of the EMW, but water takes about 70 times of that by oil alike materials under the same condition. This is the point we can detect moisture selectively from the sample body.
Of course the principle is too easy, not equal the sensor it easy to make. As our lab has being working on this technology for 40 years more, so experienced than most comrades.
BD5 Smart Transducer:Designed with the most new MCU from USA, it’s basic scientific algorithm is based on our 40 years research works, and the shell softare is designed complete according to IEEE 1451.2 STIM standard, it was original from the STIM of Honeywell.
BD4 NCAP Controller:This controller is designed according IEEE1451.1 standard. Although is not concerned to the main moisture techonology, but very powerful in high level net work application. For it is based on data communication, so not only high accuracy message can be transferred to remote office, but also can setup the transducer completely at remote control center.
l Most organic liquids
l All kinds of oil, including crude oil, fuel oil, mechanic lubricants and insulator electronic oil, and food oil
l Adhesives, Coatings , Emulsions, Inks and Dyes, Paints, Polymers, Resins,Asphalt, Glass
l Chemicals, Solvents, Pharmaceuticals
l Confectionery, Fermentation Products, Syrup
l Mineral Processing
l Oils, Oil and Gas Production, Petroleum Products , Fuel, Lubricants
l Paper Industry,Power Industry
Field Units |
Quatity |
Remote Singnal |
Human Interface |
Insertion Type Transducer Byflow Type Transducer |
1 |
0/4 to 20 mA
|
Other standard displayer |
Same |
32/128/255 |
RS485 /IEEE1451.2 |
p-BD4xCD Controller |
Same |
32/128/255 |
RS485/Modbus |
p-BD4xND Network Controller |
Same |
Popular |
RS232/RS485 |
H-Calibrator_1451.2 |
Materials Characteristics |
Application |
Suitable Technology |
1ppm-2% moisture of oil |
analysis |
MS4120 : NIR photometer |
0.01-10% moisture of oil |
analysis |
MSL1204bf: high frequicy electronic attenuation |
0.1-100% moisture of oil |
analysis |
MS1204p: high frequicy electronic attenuation |
Oil leakage,level switch |
detect |
MS1130 :high frequicy conductivity |
High desolved saults |
analysis |
MS4120 : NIR photometer |
High Electric Constancy Liquids,>40 |
analysis |
MS4120 : NIR photometer |
Oil/water interface |
monitoring |
MS1204DP : high frequicy electronic attenuation |
Level and Interface measurement |
monitoring |
LM1410: Phase difference technology |
Selection Guiding by Range
Range |
Transducer |
H_Operator |
BD4xCD Controller |
Lmixer On-line Mixer |
BD4CND Network Controller |
DSP2000 Remote Operator |
ISN2000 Instrument Station |
0-1350ppm |
TBD5xC_MSL4120 |
□ |
◎ |
|
◎ |
◎ |
◎ |
0.01-10% |
TBD5xC_MSL1204bf |
□ |
|
|
|
|
|
0.01-10% |
TBD5xC_MSL1204bf |
|
□ |
|
|
|
|
0.01-10% |
TBD5xC_MSL1204bf |
|
|
|
□ |
|
|
0.01-10% |
TBD5xC_MSL1204bf |
|
|
|
|
□ |
|
0-60% |
TBD5xC_MS1204p |
□ |
|
|
|
|
|
0-60% |
TBD5xC_MS1204p |
|
□ |
|
|
|
|
0-60% |
TBD5xC_MS1204p |
|
|
|
□ |
|
|
0-60% |
TBD5xC_MS1204p |
|
|
|
|
□ |
|
0-100% |
TBD5xC_MS1204p |
□ |
|
◎ |
|
|
|
0-100% |
TBD5xC_MS1204p |
|
□ |
◎ |
|
|
|
0-100% |
TBD5xC_MS1204p |
|
|
◎ |
□ |
|
|
0-100% |
TBD5xC_MS1204p |
|
|
◎ |
|
□ |
|
|
|
|
Key board,LCD Display 0/4 to 20 mA Output RS232/RS485 IEEE1451.2 Smart Sensor Wireless Net, Modem Accessaries. Refer to <BD4/5 Family Controller> |
On-line Mixing of liquids mixture |
Modbus Network, FFbus, ControlNet, Lonworks, Profibus, CAN field bus might surport by order. Other function is the same as BD4xCD |
Deluxe Displayer Other function is the same as BD4CND |
BigFoot WebServe included Other function is the same as DSP2000 |
u Details should refer to special materials
MS-series Liquid Moisture Technology Application
Moisture Measurement Technologic Instruments
Selection Guiding
Ref:LiqMSSel_Table_E
Version: 2001v1
|
|
|
|
|
|
Type |
Insert |
Insert |
Insert |
Flow throw |
By flow |
Model |
MS1204pp |
MS1204pc |
MSL1204pp |
NS1204H |
MSL1204B |
Connect |
ZG1”, 1”NPT Flange by order |
ZG1”, 1”NPT Flange by order |
F185 |
F150 |
ZG3/4”3/4”NPT |
Direction |
Facing flow |
Facing flow |
Facing flow |
Inlet, down Outlet, upper |
Inlet, down Outlet, upper |
Position |
Perpendicular * |
Perpendicular |
Perpendicular |
Perpendicular |
Perpendicular |
Size of insert |
440xf24 |
440 xf24 |
500 xf60 |
|
|
T.Length(mm) |
800 |
800 |
850 |
1070/H.D.600 |
760/H.D400 |
Dia. Of in/out(mm) |
|
|
|
Dg50/ Dg50 |
3/4”, 3/4” |
Weight(kg) |
4 |
4 |
7 |
30 |
25 |
Sample temperature |
100 ~350°C |
100~350°C |
100~350°C |
100~350°C |
100°C |
Sample pressure |
1.6~4.0MPa |
1.6~4.0MPa |
1.6~4.0MPa |
1.6~4.0MPa |
1.6~4.0MPa |
Range |
0.1~100% |
0.1-100% |
0.02-10% |
0.1-100% |
0.01-10% |
Resolution |
0.05% |
0.05% |
0.02% |
0.1% |
0.01% |
Repeatability |
+/-0.1% or 0.1%FS |
+/-0.1% or 0.1%FS |
+/-0.05% or 0.1%FS |
+/-0.5~1% or 0.1%FS |
+/-0.02% or 0.1%FS |
Advantage |
Versatile Simple set Well EMC |
Versatile,for viscous Small flow resis. |
High resolution Well EMC |
High moisture Average sampling |
Stable low moisture for crisis conditions |
|
|
|
|
|
|
Application |
Anywhere |
Anywhere |
Oil Union out Process |
Well field Union input |
Oil gauge Process |
l Position is described relative to earth. Horizontal is ok too if there is less bubbles inside of flow
Return to Moisture homepage
BIG DIPPER TECHNOCHEM INSTITUTE Call:(86)10-8264.0226; 8264.0225; Fax: (86)10-8264.0221; P.o.Box: 603 BDTI Beijing, China 100190 http://www.BD-research.com/ Email: support@big-dipper.us sales@big-dipper.us http://www.BD-research.com/Products/Moisture/index.htm
CopyRight Reserved
.
For quick selection to moisture measuring system, refer to <Selection Guiding>,
URL:http://www.BD-research.com/Products/Moisture/liqMoisture/LiqMS_SG_E.htm
Further Information about BD4/5xC electronics, please refer to:
URL: http://www.BD-research.com/Products/Meters/
For system design and configuration, Refer to:
URL : http://www.BD-research.com/Products/Moisture/liqMoisture/liqMS_Cfg_E.htm
For more details for selection, Refer to
URL: http://www.BD-research.com/Products/Moisture/liqMoisture/LiqMS_Sel_E.htm
To lean information of moisture detecting technology, refer to:
URL : http://www.BD-research.com/Products/Moisture/liqMoisture/liqMS_TB_E.htm
If you need help from our specialist, please down load the <User application data from>
URL: http://www.BD-research.com/Products/Moisture/liqMoisture/lMS_AS_E.htm [.doc]