Water Cut Meter Compare
Moisture
Instruments Selection
Guiding
Ref:LiqMS_AG_E
Version: 2001v1
n
All kinds of oil,
including crude oil, fuel oil, mechanic, insulator/transformer oil, lubricants
and food oil as well.
n
Most organic liquids
n
Other material’s application, please contact our
engineer engineer@fullsense.com
Water Cut Meter Compare |
Water Cut Meter Compare |
Application |
Suitable Technology |
Water Cut Meter Compare |
0-1.00 aw 0-500ppm moisture of oil |
analysis |
MS2100 : New! For water activity test |
Water Cut Meter Compare |
10ppm-2% moisture of oil |
analysis |
MS4810 : NIR photometer |
Water Cut Meter Compare |
0.01-10% moisture of oil |
analysis |
MSL1204bf: high frequency electronic attenuation |
Water Cut Meter Compare |
0.1-100% moisture of oil |
analysis |
MS1204p: high frequency electronic attenuation |
Water Cut Meter Compare |
Oil leakage, level switch |
detect |
MS1130 :high frequency conductivity |
Water Cut Meter Compare |
High dissolved salts |
analysis |
MS4120 : NIR photometer |
Water Cut Meter Compare |
High Electric Constancy Liquids,>40 |
analysis |
MS4120 : NIR photometer |
Water Cut Meter Compare |
Oil/water interface |
monitoring |
MS1204DP : high frequency electronic attenuation |
Water Cut Meter Compare |
Level and Interface measurement |
monitoring |
LM1410: Phase difference technology |
Sensor
Tech |
BD5xS |
BD5xB |
BD5xM |
BD5xMD |
|
0/4-20mA otput SCom COM |
0/4-20mA otput STIMcom |
0/4-20mA otput STIMcom Keypad and LCD function available |
0/4-20mA otput STIMcom Keypad function available LCD included |
MS2100 |
ok |
ok |
ok |
ok |
MS4120 |
N |
CG |
ok |
ok |
MSL1204bf |
NG |
CG |
ok |
ok |
MS1204p |
NG |
CG |
ok |
ok |
MS1130p |
NG |
CG |
ok |
ok |
MS1204-DP |
N |
CG |
ok |
ok |
LM1410 |
N |
CG |
ok |
ok |
N: Can not work
NR: Not recommended;
NG: only if temperature is not changing more than 10 °C around calibration temperature
CG: only if operated by Network controller, or it is equal to NG for MS1204 only.
X=C: -10 to 60 °C; x=M: -20 to 70 °C; x=I: -30 to 85 °C; x=T: -40 to 125 °C;
|
|
|
|
|
|
|
|
Technology |
HFA |
HFA |
HFA |
HFA |
HFA |
Electrochem |
NIR |
Type |
Insert |
Insert |
Insert |
Flow throw |
By flow |
Insert |
Sampling |
Model |
MS1204pp |
MS1204pc |
MS1204pm |
NS1204H |
MS1204B |
MS2123 |
MS4120 |
Connect |
ZG1”, 1”NPT Flange |
ZG1”, 1”NPT Flange |
F185 |
F150 |
ZG3/4”3/4”NPT |
ZG3/4”3/4”NPT |
ZG3/4”3/4”NPT |
Installation |
Against flow |
Against flow |
Against flow |
Inlet, down Outlet, upper |
Inlet, down Outlet, upper |
Any way |
|
Position |
Perpendicular |
Perpendicular |
Perpendicular |
Perpendicular |
Perpendicular |
Any way |
|
Size of insert |
550xf24 |
550 xf24 |
640 xf60 |
|
|
|
|
T.Length(mm) |
550 |
550 |
640 |
1060/H.D.300 |
760/H.D400 |
<500 |
|
Weight(kg) |
4 |
4 |
7 |
30 |
25 |
|
|
Sample temperature |
100 ~350°C |
100~350°C |
100~350°C |
100~350°C |
100°C |
-10~85°C |
-10~85°C |
Sample pressure |
0~4.0MPa |
0~4.0MPa |
0~4.0MPa |
0~4.0MPa |
0~4.0MPa |
0~1.0MPa |
0~1.0MPa |
Range |
0.1~100% |
0.1-100% |
0.02-10% |
0.1-100% |
0.01-10% |
0-570ppm |
0.1-4% |
Resolution |
0.05% |
0.05% |
0.02% |
0.1% |
0.01% |
0.1% reading |
0.1% reading |
Repeatability |
+/-0.1% or 0.1%FS |
+/-0.1% or 0.1%FS |
+/-0.05% or 0.1%FS |
+/-0.5~1% or 0.1%FS |
+/-0.02% or 0.1%FS |
2% reading |
2% reading |
Advantage |
Versatile Simple set Well EMC |
Versatile, for viscous Small flow resis. |
High resolution Well EMC |
High moisture Average sampling |
Stable low moisture for crisis conditions |
Trace detect |
Low range |
Application |
Anywhere |
Anywhere |
Oil Union out Process |
Well field Union input |
Oil gauge Process |
Light oil solvents |
Light oil solvents |
* Position is described relative to
earth. Horizontal is ok too if there is less bubbles inside of flow
|
|
|
|
|
|
|
|
Model |
Insert |
Insert |
Insert |
Flow
throw |
By
flow |
Insert
|
Sampling |
Type |
MS1204pp |
MS1204pc |
MS1204pm |
NS1204H |
MS1204BF |
MS2100 |
MS4120 |
Trace
water |
|
|
D |
|
C |
A |
B |
Low
range |
D |
E |
C |
F |
B |
|
A |
Middle
range |
B |
A |
C |
D |
E |
|
|
High
range |
D |
C |
B |
A |
E |
|
|
High
EMC |
B |
D |
C |
E |
A |
|
|
High
viscous |
D |
A |
C |
B |
E |
|
|
Not
uniform |
D |
C |
B |
A |
E |
|
|
Salt
various |
B |
B |
B |
B |
B |
C |
A |
Bubbles |
B |
B |
B |
B |
B |
A |
C |
Suspended |
B |
B |
B |
B |
B |
A |
C |
Composition
various |
C |
C |
C |
C |
C |
B |
A |
* A,B,C=best; …….worse,
Field
Units |
|
Remote
Signal |
|
Meters |
Design |
Evaluation |
T-BD5xS+MS |
|
0/4 to
20 mA |
|
Digitalizer |
General
application |
Economic |
T-BD5xS+MS |
|
RS485
/Scom |
|
PBD4 |
Special
appli. Sys only |
Data
acquisition |
T-BD5xMD+MS |
|
0/4 to
20 mA |
|
Digitalizer |
General
application |
Economic
|
T-BD5xMD+MS |
|
RS485/STIMcom/Modbus |
|
PBD4N |
Professional |
Network
Controller |
For more detail materials, contact us freely please J
Return to Moisture homepage
.
For
quick selection of moisture measuring system by application, refer to <Application
Guiding>,
URL:http://www.BD-research.com/Products/Moisture/liqMoisture/liqMS_AG_E.htm
URL: http://www.BD-research.com/Products/Moisture/liqMoisture/liqMSIntE.htm
Further
Information about BD4/5xC electronics, please refer to:
URL: http://www.BD-research.com/Products/Meters/
For
system design and configuration, Refer to:
URL : http://www.BD-research.com/Products/Moisture/liqMoisture/liqMS_Cfg_E.htm
To
lean information of moisture detecting technology, refer to:
URL : http://www.BD-research.com/Products/Moisture/liqMoisture/liqMS_TB_E.htm
URL:
http://www.BD-research.com/Products/Moisture/liqMoisture/lMS_AS_E.htm [.doc]
BIG DIPPER TECHNOCHEM INSTITUTE Call:(86)10-8264.0226; 8264.0225; Fax: (86)10-8264.0221; P.o.Box: 603 BDTI Beijing, China 100190 http://www.BD-research.com/ Email: support@big-dipper.us sales@big-dipper.us http://www.BD-research.com/Products/Moisture/index.htm