MS-series
Moisture Technology
Application
in Organic Liquids&Oil Industry
Ref:MS_ConfigurationE
T-BD5-xCx+MS1204_Connect
Set_Temperature_Range_Presure
p-BD4_x_y_D
p: Panel Installation
R: Field rail installation
ex: Explosive-proof rail
installation
x: weather proof degree
y=C: controller level;
XM3.5 10bit ADC LED Displayer, with slope setup function
XM4.5 12 bit ADC LED Displayer, with slope setup function
Moisture Measurement in Oil Industry Application References
Selection Guide by
Range
Range |
Transducer |
BD4xCD Controller |
Lmixer On-line Mixer |
BD4CND Network Controller |
DSP2000 Remote Operator |
ISN2000 Instrument Station |
0-1 aw 0-550ppm |
TBD5xC_MS2100 |
◎ |
|
◎ |
◎ |
◎ |
0-1350ppm |
TBD5xC_MSL4120 |
◎ |
|
◎ |
◎ |
◎ |
0.01-10% |
TBD5xC_MSL1204bf |
|
|
|
|
|
0.01-10% |
TBD5xC_MSL1204bf |
□ |
|
|
|
|
0.01-10% |
TBD5xC_MSL1204bf |
|
|
□ |
|
|
0.01-10% |
TBD5xC_MSL1204bf |
|
|
|
□ |
|
0-60% |
TBD5xC_MS1204p |
|
|
|
|
|
0-60% |
TBD5xC_MS1204p |
□ |
|
|
|
|
0-60% |
TBD5xC_MS1204p |
|
|
□ |
|
|
0-60% |
TBD5xC_MS1204p |
|
|
|
□ |
|
0-100% |
TBD5xC_MS1204p |
|
◎ |
|
|
|
0-100% |
TBD5xC_MS1204p |
□ |
◎ |
|
|
|
0-100% |
TBD5xC_MS1204p |
|
◎ |
□ |
|
|
0-100% |
TBD5xC_MS1204p |
|
◎ |
|
□ |
|
|
|
Key
board,LCD Display 0/4
to 20 mA Output RS232/RS485
IEEE1451.2
Smart Sensor Wireless
Net, Modem Accessaries. Refer
to <BD4/5 Family Controller> |
On-line
Mixing of liquids mixture |
Modbus
Network, FFbus, ControlNet, Lonworks, Profibus, CAN field bus might surport by order. Other
function is the same as BD4xCD |
Deluxe
Displayer Other
function is the same as BD4CND
|
BigFoot
WebServe included Other function is the same as DSP2000 |
l
Details should refer to special materials
l
For more details, please refer to 《Moisture Measurement Technologic
Instruments Selection Guiding》, LiaMS_AG_E.
Thread for
P type |
Flange for
P type |
Flow
Through |
By Flow |
NPT1" or ZG1" |
Flange 150mm,185mm |
Flange 150 |
NPT3/4" or ZG3/4" |
T100 |
T200 |
T300 |
Sample Temperature: <100 ºC Max<120 ºC for short time overwork |
Sample Temperature: <200 ºC Max<240 ºC for short time overwork |
Sample Temperature: <300 ºC Max<400 ºC for short time overwork |
_1.6T |
_1.6F |
_4.0F |
Sample presure: <1.6 MPa |
Sample presure: <1.6 MPa |
Sample presure: <1.6 MPa (only Flange
available |
C |
M |
I |
T |
Temperature:0-50 ºC Humidity: 0-100 %RH |
Temperature:-10-70 ºC Humidity: 0-100 %RH |
Temperature:-30-85 ºC Humidity: 0-100 %RH |
Temperature:-40-125 ºC Humidity: 0-100 % RH |
Transducer |
p-BD4-Controller |
Ex-PS Power
Supply |
Related
Device |
Ia, |
No |
No |
By Device related |
Ex Class
Field |
Submersion |
At Field |
Safe Area |
Safe Area |
Ex-001/005/016/017/BP12/A013 for
BD4/5_C_S/C |
TS1 for BD5xS |
IP-A09/A012/B01 for BD4/5_x_S/C_D |
B03,PC23 for BD4/5_x_S/C_D |
p-1651 for BD4/5_x_S/C_D |
EX Ia |
Water and Presure Proof |
Water proof |
?? |
?? |
Class 1,Group A/B/C/D(PL) Class II,Group E/F/G(AL) NEMA 7, for BD4/5_C_S/C,PL NEMA 8, for BD4/5_M_S/C,PL NEMA 9, for BD4/5_M_S/C,AL |
NEMA 6/6p IP67 |
NEMA 2,3/3S,4/4X,12/12K,13 NEMA 3R; NEMA 5; IP 11,56,52,54; IP14 |
NEMA 1 IP10 |
NEMA 1 IP10 |
Note:
·
Further Information about BD4/5xC electronics, please
refer to the related information
·
Though BD5 Transducer is one independent Analyzer, but
you'd better not operate it in Explosive area.
·
Each BD4xCD Controller can control up to 247 BD5
Transducers.
l
For more details, please refer to 《Moisture Measurement Technologic
Instruments Selection Guiding》, LiqMS_AG_E.
Return to Moisture homepage