Ref:MS2100IntE
Version:2002-01-08
___IEEE1451.2 STIM Compatible, 1451.1 NCAP and
Modbus Network support. Analog and Digital Signals Output. Remote Setup
and Operate.
n
Continuous analysis.
Direct measurement in sample way
n
Multi-parameters
test: water activity, water content/moisture, separation point, and temperature
as well.
n
Accurate and
reliable, rugged design, low-maintenance
n
Quickly response,
<15 sec at typical cases
n
Self diagnostic,
professional intelligent, Menu-driven digital user interface
n
Auto diagnostic and
alarm
n
Data log of
measurements for day/month/year
n
One-year warranty
MS2100 is a fast, reliable and accurate on-line detection system
for water in organic liquids, oil, etc.
Low limit moisture on-line test has
been always troubles in some crisis industry process. Both of on-line and
laboratory analyzers are expensive, and time costing in the past time.
It was hoped to replace some
process instruments at certain cases, to save lots of equipment investment and
maintenance cost. What is most important is it's easy way to test directly and
real time response, and also excellent accuracy. Speed is very important in
modern chemical process.
The system measure
water activity, water content/moisture, separation point (equal to dew point in
air moisture), and temperature as well. With T-BD5xMD STIM, all these
parameters can be displayed at field, and could be read by NCAP controller in
remote area. The analog signal output port of the transmitter could be set to
output one of these parameters, such as water activity, moisture or separation
point by user selection.
Water Activity is a relative
parameter for moisture. In some application, it is more obvious than
traditional absolute terminology, for it is directly meaning the possibility to
happen of water separation. Water formation is often critic accident for
processes.
Separation Point is one concept determined
by our institute. Thought it is not so concerned as Dew Point, but also
convenient for some applications. For it is more easy to compare the separation
point with the sample temperature, so that to estimate the risk of the system
by operators.
As to application for
transformer oil, water activity measurement offers several advantages compared
to the traditionally measured variable, parts per million (ppm). Water activity
indicates directly whether there is risk for free water formation. The measurement
is 97% independent of the oil type, aging , and compensated by temperature
algebra.
l
water activity for organic liquids
l
Separation point alarm
l
Trace
water content/moisture analysis
l
Not necessary to calibrate
l
High accuracy
l
Fast response
l
Stable, low drift performance
l
Chemically resistant
l
BD5 CPU based STIM, perfect design with complete instrument functions
l
Auto temperature compensation
l
Linear analog signal output, 0/4 to 20 mA select. default status is 0
to 20 mA for activity. Moisture and Separation point output is selective for
users.
l
RS232 serial port always available
l
RS485 with STIMcom or Modbus protocol attached to BD5xB upper
configuration. BD5s has simple SCom data communication ability.
l
Power supply: DC 9 to 24 V; consumption <100 mW at Max.
l
Intrinsic safe design
l Transformer Oil
l Machine oil or lubricants
l Other organic liquids
l Moisture leak detection
Note: For more chemicals application rather
than oils, please contact our engineer for verification.
Technical specifications
l
Measurement range:
0...1 aw; 0...80 to 550 ppm relative
to temperature;
l
Accuracy: ±10% of reading,
0-1.00 aw, 25 °C
l
Operating temperature:
MS2123N:
-40 to 85 °C
MS2123p:-40...+180 °C
l
Working Pressure: N:<0.3 Mpa; p:<1.0 Mpa
l
Sensor Interchangeability: ±5% of reading
l
Hysteresis ±12% of reading
l
Repeatability ±5% of reading
Environal Humidity:
Operating:0 to
100% RH, non-condensing
Storage:0 to 90%
RH, non-condensing
Environal Temperature Range:
N:Operating -40
°C to 85 °C (-40 °F to 185 °F)
N:Storage -51 °C
to 125 °C (-60 °F to 257 °F)
T001-BD5xMx+lMS2100N
|
T-BD5CMD |
T-BD5MM |
T-BD5IB |
Environal Temperature |
-10 to 60 °C |
-30 to 70 °C |
-40 to 85 °C |
Environal Humidity: |
10-90% |
0-100%( non-condensing) |
0-100% |
* if with LCD, the environal is -10 to 60 °C, 10-90%
Safety: Ia, intrinsic designed. Could be used at
Class 1,Group A/B/C/D;Class II,Group E/F/G;
Package: NEMA 7, NEMA 8,
NEMA 9,NEMA
6/6p,IP67
MS2123 series
T001-BD5CMD+lMS2123N Insertion Moisture
Transmitter Sampling temperature: -40 to 85°C Sampling pressure: <0.3Mpa Insertion length: 40- 200mm Installation connect: ZG1” /1”NPT |
|
|
T001-BD5CMD+lMS2123p Insertion Moisture
Transmitter Sampling temperature: -40 to 180°C Sampling pressure:
<1.0 Mpa Insertion length:200mm Installation connect: ZG1” /1”NPT |
|
|
H-BD5MS2123N Trace Moisture
Transmitter Temperature and moisture test Lab test or In sito smart test |
|
|
Return to Moisture homepage